Variety of mechanically held lighting contactor wiring diagram. One type of contactor is an electrically held contactor which is similar to a magnetic starter.
Four Pole Contactor Diagram Wiring Diagrams
Mechanically held lighting contactor diagram. Wide range of coil voltages from 24 to 600 vac 5060hz. Positions 1 thru 4 on the base may be configured as either normally open no or normally closed nc while positions 5 and 6 may be configured as no onlylighting contactor mechanically and electrically held. Lighting contactor wiring diagram withtocell 1400 771 with cell. Low input va permits long wire runs verifies contact status and has built in delays that minimize excessively frequent signals from faulty controllers come in a wide range of input voltages. A wiring diagram is a simplified standard pictorial depiction of an electric circuit. Rated for tungsten lighting incandescentfi lament ballast lighting fluorescent hid metal halide mercury vapor quartz halogen and sodium lamp resistive and general use loads.
It shows the elements of the circuit as simplified forms as well as the power and also signal connections in between the gadgets. Square d 8903 lighting contactor wiring diagram diagram 5ab6fcdb9a69 square d 8903 hey mike g ray again what would make a mechanically held in with lighting contactor wiring file type. Mechanically held contactor mechanically held usually require additional control relays to operate with photo eyes. Most lighting and heating applications require a contactor to control the loads. Electrically held contactors siemens contactor type clm. When used with building automation controllers a mechanically held requires both an on and an off contact in a super quite area like a broom closet in a library you might hear the coil hum from a electrically held device so a.
Mount lighting contactor in the vertical position only as shown below. Unlike a magnetic starter however a lighting and heating contactor is designed for lighting and resistive. Sufficient room is provided in all enclosure styles for the addition of a power. Only one power pole can be added per contactor. Lighting contactor wiring diagram collections of wiring diagram contactor fresh wiring diagram overload relay fresh. Factory assembled 4 and 5 pole contactors use the basic 3 pole device with a single pole or double pole kit installed.
It also ensures the removal of coil from the circuit for noise free operation and the elimination of all coil losses. Four modules cover input voltages from 24 277 vac and 12 24 vdc. The mechanically held operation ensures that the contactor will not switch to off during control power failure. Electrically and mechanically held. Mechanically held lighting contactor wiring diagram download. 2 12 pole configurations depending on contactor size.
Lighting contactors mechanically held contactor a two or three wire control module. The c30cn 30a mechanically held lighting contactors are designed for industrial commercial and outdoor lighting applications where efficient control is required. A maximum of 12 poles may be installed on the base. Wiring diagram for lighting contactor inspirationa refrence wiring. Type s lighting contactor to make a 4 or 5 pole device. Contacts are rated 20 400 amps at 600 volts.