Check resistance from t13 t4. It should be some small number.
3ph Motors Single Speed
12 lead generator connection diagram. The connections to the switch must be made so. 101112 dual voltage external wye connection voltage conn. Delta voltage hz l l 60 2402 7967 50 1905 6351 double delta single phase connection j voltage hz l l l l0 60 200 100 220 110 240120 50 220 110 parallel low zigzag single phase. It should be some small number. 12 lead generator connection diagram 51 kb magnaplus dimensions 51 kb sae engine adapter and flywheel coupler measurement guide 162 kb generator sizing information. 12 lead generator procedure reference connection diagram 14002 31.
This should be almost zero. This should be almost zero. If t16 t4 is almost zero swap the lead numbers from t13 and t16. 3 lead y 3 lead delta 6 lead y 6 lead delta 9 lead high voltage y 9 lead low voltage y 9 lead high voltage delta 9 lead low voltage delta 12 lead high voltage y 12. 12 lead technical data connection diagrams series high wye parallel low wye wye series high delta voltage hz l l l l0 60 190 110 208 120 220 127 230 133 240 139 50 190 110 200 115 208 120 220 127. Collection of 3 phase motor wiring diagram 12 leads.
It should be a little bit smaller or about the same if not easily detectable. In order to supply you with the correct generator end our staff will need you to supply the following information. Check resistance from t13t4. 12 lead generator procedure reference connection diagram 14002 31. Then check from t4 t16. Then check from t4 t16.
Equal to 50 of the generators three phase ratings. 12 lead 11 8 t 9 t 12 t 7 t 10 l l0 l l l l0 l l l0 j single phase kwkva ratings are approximately equal to 50 of the generators three phase ratings. It should be a little bit smaller or about the same if not easily detectable. Compound generator all connections are for counterclockwise rotation facing the end opposite the drive. A wiring diagram is a simplified traditional pictorial depiction of an electrical circuit. For clockwise rotation interchange a1 and.
L1 l2 l3 join high wye 1 2 3 475869 101112. It reveals the components of the circuit as simplified shapes and the power as well as signal connections between the gadgets. If t16 t4 is almost zero swap the lead numbers from t13 and t16. 10 and 12 lead low wye available voltages iso standard 10 lead generators are identical to 12 lead generators with the exception that u6 v6 and w6 are permanently bonded together as n 240v connections shown in blue 208v connections shown in red u n v u5 u2 v v w u6 u1 v1 v2 v5 v6 w1 w2 w6 w5 240v 208v.