This means that typically single phase motor current will be at least double that of 3 phase motors of similar power output. In the above three phase dol starter wiring diagram.
Sizing The Dol Motor Starter Parts Contactor Fuse Circuit
3 phase dol starter connection. It is an easiest method for starting up three phase induction motor in which stator windings of the motor are connected directly to the main supply. As the power ratings of our starters are based on 415vac 3 phase it becomes necessary to base starter selection on the full load current of the motor and not the power rating. I dol starter wiring connection with start and stop buttons are shown in the above figure 1. This is the wiring diagram of a dol starter. I have 24vdc coil 5 amp resistive load on 8 qty connected to my plc card this is smoke extraction system and there are five zone with five different plc installed each zone has eight 3hp fans working in primary and secondary configuration. The contactor has 3 types of contacts.
Mccb or circuit breaker. When an induction motor is connected to the three phase supply a very large current typically 5 to 8 times the full load current flows through the motor. A dol starter or direct on line starter or across the line starter is a method of starting of a 3 phase induction motorin dol starter an induction motor is connected directly across its 3 phase supply and the dol starter applies the full line voltage to the motor terminals. The dol starter joints the 3 phase main wiring with the induction motor namely l1 l2 and l3 when the start switch is pressed. Three phase dol starter wiring diagram. Between the mains supply terminals and motor terminals the dol starter main terminals are connected and with the two terminals of the three phase power supply as described in figure 1 the control circuit is energized.
And one wiring is called controlling wiring. The contactor has 3 main no contacts known as l1 l2 and l3. I am facing problem of operation of dol starter 3 phase 3 hp motor through plc. What is dol starter. In the below dol starter wiring diagram i shown a molded case circuit breaker a magnetic contactor normally open push button normally close push button switch thermal overload relay motor trip indicator and 3 phase motor. The 3 phase dol starter wiring diagram is shown below.
Generally the direct online starter working can be done in two different stages namely dol starter control circuit and dol starter power circuit. Despite this direct connection no harm is done to the motor. The r y and b phase are connected through mccb to the contactors.