Question is not about how to connect. As a part of the am2 exam you will have to wire up a 2 way and intermediate lighting circuit with one light.
P05042b
Am2 lighting circuit diagram. Describe the meaning of the 2 in diagram component s. In modern domestic properties in the uk the main electric lighting circuits are separate from the power ring main circuit. Turnsignals hazard page l 2 3. The ground points circuit diagram shows the connections from all major parts to the respective ground points. Each house should ideally have at least two lighting circuits. As you can see the circuit starts and ends at the consumer unit.
Basics of uk lighting circuits connections to ceiling rose and light switch. There is more than one way to do this depending of the type of cable available and on the installation requirements. Follow this link if you are looking for a comprehensive step by step guide on two way and intermediate lighting circuit wiring. Otherwise continue with the am2 exam guide. Sometimes the layoutterminal identification on the intermediates can varying depending on the brands so try not to let that throw you on the day. Draw in green the horn control circuit from the battery to ground.
I failed lighting circuit at am2. Describe the meaning of the g w in diagram component r. Please observe the wiring diagram above. Draw in red the horn circuit from the battery to. Best of luck mate you doing the am2 or am2s. The relationship between ground points and oy shown below can also be checked.
Videos are training aids for city and guilds c. Stop lights page l 3 4. Youre right the neutrals need to be wired through the switches. I wired my lighting circuit exactly like your diagram above. Always isolate any electrical circuit before working on the circuit. Each protected by a 5 amp fuse or 6 amp trip in the consumer unit.
I had intermediate switching with trunking plastic switches 2x two way switches 1x intermediate switch in plastic conduit boxes using 6242y and 6243y cables and round celling light with strip connectors. Headlights page l 1 2. It goes around the house or a room and connects to all the sockets and fused connection units fcus required to be on the ring main circuit. 2 way and 2 way and intermediate connections explained. When troubleshooting a faulty ground point checking the system circuits which use a common ground may help you identify the problem ground quickly. The circuit is wired in twin and cpc cables twin and earth cable and 3 core and cpc cable.