Size of over load relay. 1up to 75 hp dol starter industrial application one contactor are used 2up to 75 to 20 hp star delta star delta starter three contactor are used and one stardelta timer are used mccb three contactor over load relay timer spp single phase priventer control fuse.
Star Delta Starter Working Principle Theory Circuit Diagram
Single line diagram star delta starter. The most common voltage combinations are 220380v ac and 277480v ac. Star delta connection diagram and working principle. In the line is the same as just putting the overload before the motor as with a dol starter. Star delta starter can be used only for low to high power three phase induction motors. Star delta uses two contactors one to start at a lower voltage in star and one to run at a higher voltage in delta configuration. Star delta starter control circuit in this videoi have explained about why we use star delta starter what should be the rating of motor above which we use star delta starterwhy we connect first.
Star delta starter wiring diagram this post is about the main wiring connection of three phase motor with star delta starter and control wiring diagram of star delta starter. This is a big advantage of a star delta starter as it typically has around 13 of the inrush current compared to a dol starter. A dual starter connects the motor terminals directly to the power supplyhence the motor is subjected to the full voltage of the power supplyconsequently high starting current flows through the motor. But high load 3 phase motor we use the star delta starter for motor. The peak starting current is 13 to 26 of full load current. And connection diagram typically indicate wye delta or star delta but there may also be references to low volts and high volts.
A dol starter or direct on line starter or across the line starter is a method of starting of a 3 phase induction motorin dol starter an induction motor is connected directly across its 3 phase supply and the dol starter applies the full line voltage to the motor terminals. What is dol starter. Size of each part of star delta starter 1. For example a 400v 3 phase power supply star applies phase to neutral or 230v. A single voltage wye delta motor typically has six leads that are marked t 1 through t 6. In comparison a standard.
Characteristics features of star delta starter. The starting current is 33 of full load current for star delta starter. For a star delta starter there is a possibility to place the overload protection in two positions in the line or in the windings. For three phase motor we use the direct online starter but mostly for small three phase motor. Overload relay in line. This type of starting is suitable for small motors below 5 hp 375 kw.
The peak starting torque is 33 of full load torque. A star delta starter is a type of reduced voltage starterwe use it to reduce the starting current of the motor without using any external device or apparatus. Despite this direct connection no harm is done to the motor.