Flex io helps eliminate multiple long wiring runs reduces terminations per. Channel 0 terminals 0 1 and 17 example of 3 wire thermocouple wiring to a 1794 tb3t temperature terminal base unit 0 15 1633 3451 1794 tb3t cold junction compensator allen bradley pn 96942401 2 supplied with module channel 0 terminals 0 1 and 39 publication 1794 657.
Download Allen Bradley 1794 Oe12 Manual Kindle Manual
1794 ir8 wiring drawing. For more accurate readings in mv mode. Wiring to a tbn or tbnf terminal base unit. Our bulletin 1794 flex io modules offer flexibility for your application with digital analog hart analog and specialty io with 432 points per module. Keep exposed area of inner conductor as short as possible. Wire off over range and under range detection good common mode rejection usage with long thermocouple wiring effective in noisy environments usage with grounded or ungrounded thermocouples more stability with ambient temperature changes than with the 1794 ir8 and the 1794 it8. 1794 ir8 rtd input module the 1794 ir8 is a temperature measuring module that accepts 2 and 3 wire rtds.
Use the 1794 ir8 in applications where channel fast update rate is not required. Rtd input module specification 1794 ir8 input resolution 16 bits across. The 1794 irt8 offers the following. Connect individual output wiring to numbered terminals on the 0 15 row a as indicated in the table below. 2 rockwell automation xxxx flex io high density analog modules user manual connect wiring to the ie8 the associated terminal on row b. Example of 2 3 and 4 wire rtd and thermocouple wiring to a 1794 tb3g terminal base unit 1794 tb3g terminal base unit thermocouple channel 4 2 wire rtd channel 1 3 wire rtd channel 2 4 wire rtd channel 3 0 15 16 33 34 51 1794 tb3g attention.
Offering a powerful range of product drawing tools to help you design apply our products. Publication 1794 in100b en p june 2004 installation instructions flex io input output and inputoutput analog modules cat. Connect individual high and low signal wiring to numbered terminals on the 0 15 row a as indicated in the table. 1794 tb32 and tb32s terminal base wiring for the 1794 ib16d wiring for 1794 ib16d use with 1794 tb32 or tb32s terminal base units connecting wiring for the 1794 ob16d using 1794 tb2 tb3 or tb3s terminal base 1. Connecting wiring for 1794 tb2 tb3 tb3s tb3t and tb3ts terminal base units 1. Connecting wiring for the analog inputs and outputs.
If you need channel fast update rates use the 1794 irt8 module described on page 44. Available on line or for download our tools help you access information while in the office or on the go. Use belden 8761 cable for mv signal wiring or the appropriate thermocouple wire for your thermocouples. You can mix and match digital and analog io with mounting and wiring options. 1794 ie8 ie8k oe4 oe4k and ie4xoe2 series b modules with a k in the last position of the catalog number are.