In this diagram a three phase unity pf load resistive load is supplied by two transformers. Another configuration is known as the delta for its geometric resemblance to the greek letter of the same name δ.
Nb 0381 Hi Leg Transformer Wiring Diagram
Open delta wiring diagram. It is called orange leg because the wire is color coded orange. Open delta transformers are three phase devices with only two windings on each of the primary and secondary sides. Take close notice of the polarity for each winding in the figure below. The above figure shows the connection diagram of an open delta system. Looking at the open delta diagram and using kcl node equations the a line current is now equal to b phase current minus the c phase current. This means an open delta transformer will only be able to deliver 577 of the capacity of an equivalent three phase delta transformer with similar voltage and load current.
Three phase three wire δ connection has no common. More insulation is required and the voltage appearing between windings and core will be equal to full line voltage in case of earth fault on one phase. While cheaper than a conventional three winding transformer the open delta will only deliver 577 of the power of a conventional transformer not two thirds 667 as may be expected. Regular 3 phase delta looks like this. A free training video from northwest lineman college wwwlinemanedu. The three phase power is connected in the delta configuration and the center point of one phase is grounded.
V p phase voltage v l line voltage i p phase current i l line current r r1 r2 r3 resistance of each branch w wattage w delta 3 w wye w odelta ¾ w delta w owye ½ w wye. Disadvantages of delta delta transformer connection. Most utility companies will not hook up 3 phase delta on the customer side anymore because the the high or wild leg which as shown in the diagram runs a good deal higher than 120 volts to neutral. Each transformer is rated as 10 kva current rating is 10 a and voltage rating is 1000 v. We will use a phase current magnitude of 1 so that we can plug these values into our calculator and solve to see if the magnitude or angle increases or decreases with this new kcl relationship. For both wye and delta balanced loads wye and delta equivalent.
Connection diagram of open delta transformer. Alternate way of stating the same is that if a delta delta transformer is converted to open delta transformer then the new transformer will only be able to supply 577 of. This creates both a split phase single phase supply l1 or l2 to neutral on diagram at right and three phase l1 l2 l3 at right. 3 phase delta power. Due to the absence of neutral point it is not suitable for three phase four wire system. This video explains the correct and proper wiring of open delta open delta transformer banks.
3 phase open delta power.